21
6.3. Monthly.
Glass door seal and gaskets
It is important that the glass door seal, the ash
pan gasket and pellet tank cover seals tightly,
as the stove requires underpressure in the
combustion chamber for correct operation.
The glass seals must be replaced if worn, or
glued in place using ceramic glue if loose.
Ask your dealer if you need assistance
6.4. Semi annually / Annually
Emptying / Cleaning of the pellet tank.
Pellettank should be emptied and vacuumed for
dust and pellet remains at least semiannually
Internal flue pipe and chimney fan (*)
The stove’s internal flue pipe must be kept free
from ash and soot.
Remove the chimney fan and clean any ash or
soot off the housing and blades.
Cleaning the Pressostat: (*)
The pressostat is connected to the chimney fan
by a silicone hose. Clean the silicone hose if dirty
using water and soap (ensure it is completely dry
before reinstalling). Apply suction to the pressos-
tat inlet and listen to hear if it clicks.
Cleaning the convection fan (*)
Check that the convection fan turns easily by
turning it with your fingers. Clean off dust and
any other dirt, for example using a soft brush.
Cleaning the flue gas channel (*)
Clean the flue gas channel using the round steel
brush supplied with the stove. Vacuum any ash
remainings inside the inspection hole at the front
bottom of the stove.
Items marked (*) should only be made by an
authorized dealer, however, there may be special
circumstances that cause the frequency of clea-
ning these components to be more frequent than
indicated here if the environment where the oven
is installed requires this. This can be done by the
customer by agreement.