DEFINITIONS
Acoustic signal A buzzer or other sound intended to be heard as an alert.
Analog signal Proportional - stepless or infinite control
Belly box A transmitter that is secured to the front of the operator’s body by a belt,
strap or breastplate/harness.
Coder Converts parallel signals into a serial data message
Decoder Coverts a serial data message into parallel signals
Digital signal On/off control
Latching control The function activates when the control is pushed and released. The function
stays on until the control is pushed and released again.
Mainline contactor The primary power supply contactor to the crane/machine controls.
Maintained control The function activates when the control is placed in the ON position. The
function stops when the control is placed in the OFF position.
Momentary control The function activates when the control is placed in the ON position. The
control must be held in place to stay ON. When the control is released, it
returns to the OFF position and the function is stopped.
Proportional control A multi-speed function control that goes faster as the control is pressed
further.
AWG - METRIC CONVERSIONS
AWG Metric Equivalent mm sq. Metric Cable Size mm sq.
20 0.52 0.75
18 0.82 1.0
16 1.32 1.5
14 2.1 2.5
12 3.3 4
10 5.32 6
8 8.5 10
6 13.5 15
4 21.3 25
2 33.7 35
1/0 (0) 53 70.0 (50.0 if current capacity not
exceeded)
2/0 (00) 67.6 70
3/0 (000) 84.4 95
4/0 (0000) 107 120