C.8 868MHz Fixed Frequency Channel Table
D2 D3 D4 D5 D6 Frequency (MHz) Channel No.
0 0 0 0 0 869.3000 52
0 0 0 0 1
869.3250
53
0 0 0 1 0
869.3500
54
0 0 0 1 1
869.3750
55
0 0 1 0 0
869.4000
56 S1 = 0 : Manual/Fixed Channel
0 0 1 0 1
869.7000
68 S1 = 1 : Automatic Channel
0 0 1 1 0
869.7250
69 D2 = 1 : FCS TX and Scan-RX
0 0 1 1 1
869.7500
70 D3 = 1 : AUTX and Scan-RX
0 1 0 0 0
869.7750
71
0 1 0 0 1
869.8000
72
0 1 0 1 0
869.8250
73
0 1 0 1 1
869.8500
74
o 1 1 0 o
869.8750
75
0 1 1 0 1
869.9000
76
0 1 1 1 0
869.9250
77
0 1 1 1 1
869.9500
78
1 0 0 0 0
869.9750
79
1 0 0 0 1
870.0000
80
1 0 0 1 0
869.4250
57
1 0 0 1 1
869.4500
58
1 0 1 o o
869.4750
59
1 0 1 0 1
869.5000
60
1 0 1 1 0
869.5250
61
1 0 1 1 1
869.5500
62
1 1 0 0 0
869.5750
63
1 1 0 0 1
869.6000
64
1 1 0 1 0
869.6250
65
1 1 0 1 1
869.6500
66
1 1 1 0 0
869.6750
67
1 1 1 0 1 868.0000 0
1 1 1 1 0 868.2050 10
1 1 1 1 1 868.5000 20
C8.1 868MHz Automatic Frequency Channel Table
D4 D5 D6 Channel No. within Scan-Group Scan-Group No.
0 0 0 75, 71, 68, 54, 52 1
0 0 1 76, 72, 69, 55, 53 2
0 1 0 79, 77, 73, 70, 56 3
0 1 1 78, 76, 73, 69, 55 4
1 0 0 66, 62, 59, 57 5
1 0 1 67, 63, 60, 58 6
1 1 0 24, 19, 16, 7, 3, 1 7
1 1 1 23, 18, 15, 6, 2, 0 8
Allowed duty cycle 100%
Allowed duty cycle 10%
Allowed duty cycle 1%
Note: This frequency
allocation is designed for
use in Europe Non-
License Band.
For use in different
countries, please check
with local authority
.

Table of Contents