User manual for poly-phase meter
30
Before battery replacement, must power off the meter first, otherwise it
may threat life. Make sure in replacement process, power grid will not
power on by mis-operation.
2 Open communication module cover.
3 Remove the battery to be replaced.
4 Plug in the new battery.
5 If the display of meter works, it means new battery installation is correct.
6 Close communication module cover.
7 Power on the meter.
To ensure battery replacement will not make any influence to RTC of
the meter, please try to finish battery replacement in a short period
(within 20s is recommended), or after battery replacement, use PC
software or HHU to write RTC of the meter.