User manual for poly-phase meter
11
7 Demand
7.1 Calculation method of MD
Support two types of MD calculation methods: sliding window time and block.
MD sliding time can be set between from 1 to 60 minutes, and MD sliding number
can be set between 1~15, and the sliding time and number should not be more than 60
by multiplication.
7.2 MD recorded content
Import active demand
Export active demand
Import reactive demand
Export reactive demand
Reactive demand in QI
Reactive demand in QII
Reactive demand in QIII
Reactive demand in QIV
Import apparent demand
Export apparent demand
Active demand (|QI+QIV|+|QII+QIII|)
Import active MD with time stamp total and per tariff
Export active MD with time stamp total and per tariff
Import reactive MD with time stamp total and per tariff
Export reactive MD with time stamp total and per tariff
Reactive MD with time stamp total and per tariff in QI
Reactive MD with time stamp total and per tariff in QII
Reactive MD with time stamp total and per tariff in QIII
Reactive MD with time stamp total and per tariff in QIV
Import apparent MD with time stamp total and per tariff
Export apparent MD with time stamp total and per tariff
Active MD (|QI+QIV|+|QII+QIII|) with time stamp total and per tariff