DST, meter time shall be adjusted in 1 hour later.
When set the DST parameters or change the meterās clock, the meter starts to
work hourly under DST setted.
15.2 TOU
Support 4 tariff rates.
Support maximum 50 holidays.
Holidays can be divided into two types: special yearly holiday and public yearly
holiday. Special yearly holidays work only in specific years, while public yearly
holidays work through the current and future years.
Maximally 6 season tables can be configured for each year, and each season
corresponds to a weekly time table.
Maximally 8 weekly time tables can be configured, and each weekly time table
supports separate configuration of daily time table from Monday to Sunday.
Maximally 8 daily time tables can be configured, and each daily time table
supports configuration of up to 8 time periods. Configuration of crossing zero is also
available.