EasyManuals Logo

Hi-Link HLK-RM04 User Manual

Hi-Link HLK-RM04
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Hi-Link (HK)Co.,Ltd sky:hlktech
Http://www.hlktech.net Tel:0755-23152658-821
28
At+uart=<baud><data><parity><stop>\r
parameters
BaudBaud rate
DataData bits
ParityParity bit
Stoplength of stop bit
6.2.19 uartpacklen
Function
Serial framing length setting
Format
At+uartpacklen =<uartpacklen>\r
Parameters
uartpacklenSerial framing lengthUnitbit.Default value: 64.
6.2.20 uartpacktimeout
Function
Serial framing time setting
Format
At+ uartpacktimeout=<uartpacktimeout>\r
Parameters
uartpacktimeoutSerial framing timeunitms)。 Default value:10
6.2.21 escape
Function
Serial exiting the Pass-through enable
Format
At+ escape=<escape>\r
Parameter
escape0 - close1 - enable
6.2.22 tcp_auto
Function
TCP automatic reconnection
Format
At+ tcp_auto=<tcp_auto>\r

Table of Contents