EasyManua.ls Logo

HID EDGE EVO EH400-K - Mounting; Wiring

HID EDGE EVO EH400-K
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION GUIDE
An ASSA ABLOY Group brand
EDGE EVO 82000-921, Rev. D.3
Page 5
2 Mounting
3 Wiring
Hi-O Group Select Jumper
Short = Group 1, Open = Group 2
Outside Door Inside Door
(
)
1 P2 12 1 P1 4
CAN V+
GND
CAN_H
CAN_L
RDR PWR
GND
Data0 / Data
Data1 / CLK
*
GRN LED
RED LED
Hold
*
Beep
GRP SEL
+
-
10 P3 14 P1 1
+
-
Hi-O Group Select Jumper
Short = Group 1, Open = Group 2
Outside Door Inside Door
( )
+
-
*
NC
NO
COM
NC
NO
COM
Relay Jumpers
6 P10 1
AUX
+DC
AUX
GND
+
-
Reader Tamper +
Door Strike
AUX
AC FAIL
INPUT SENSE
REX
Door Mon
* = Built-In Module Internal Optical Ta mper Disable
BATT FAIL
INPUT SENSE
Note: Connect the Door Monitor to avoid a Force Door Alarm.
P9
P5
P8
P6
P4
P7
Ethernet / PoE
Auto-Detected
Activity LED
Link LED
Hi-O CANbus
Reader Tamper -
CAP
Restore Network
Defaults Jumper
CAUTION: Some magnetic locks exhibit both high inrush current when activated and a high
instantaneous break voltage when de-energized due to magnetic field collapse. It is recommended
you use of a snubber circuit across the controlling relay terminals to protect the controlling relay
contacts. Go to www.hidglobal.com > Support and search for "Edge Solution 891" to access How do I
wire a High In-Rush Current locking device to VertX/EDGE EVO. Not evaluated by UL.
Optional
Supervised Inputs
1-6K
N/O
1-6K
N/C
1-6K
1-6K
N/O
Legend
CAN_H = Hi-O CANbus High
CAN_L = Hi-O CANbus Low
GND = Ground
CAN V+ = Hi-O CANbus Positive
Supply
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
Junction box not included.

Related product manuals