159
Figure 8-14 Video Quality Diagnostics Interface
Step 2 Check the checkbox of Enable Video Quality Diagnostics.
To enable video quality diagnostics, the function should be supported by the selected camera.
Step 3 Enable and set the threshold of the diagnostic types, there are Blurred Image, Abnormal
Brightness, and Color Cast.
Check the corresponding checkbox of the diagnostic type, and adjust the threshold of it by
dragging the bar.
The higher the threshold you set, the harder the exception will be detected.
Step 4 Click to set handling method of video quality diagnostics. Set arming schedule and
alarm response actions of the channel.
1) Click Arming Schedule tab to set the arming schedule of response action.
2) Choose one day of a week and up to eight time periods can be set within each day.
Time periods shall not be repeated or overlapped.

Table of Contents

Other manuals for HIKVISION DS-7208HGHI-F1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7208HGHI-F1 and is the answer not in the manual?

HIKVISION DS-7208HGHI-F1 Specifications

General IconGeneral
Product colorBlack
Rack capacity1U
Channels quantity8 channels
Remote control type128
Video capturing speed30 fps
Audio formats supportedG.711
Maximum video resolution1920 x 1080 pixels
Video compression formatsH.264, H.264+
Playback resolutions supported1080p lite
BNC input ports8
USB 2.0 ports quantity2
Ethernet LANYes
Ethernet interface typeFast Ethernet
Supported network protocolsTCP/IP, PPPoE, DHCP, Hik Cloud P2P, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP, HTTPS
HDD interfaceSerial ATA
Maximum HDD capacity6000 GB
Power consumption (typical)12 W
Storage temperature (T-T)10 - 90 °C
Operating temperature (T-T)-10 - 55 °C
Weight and Dimensions IconWeight and Dimensions
Weight1000 g
Dimensions (WxDxH)260 x 222 x 45 mm