Figure 6-24 Set Arming Schedule
3. Click Apply.
6.4.4
Congure Alarm Linkage Acon
Congure Full Screen Monitoring
When an alarm is triggered, the local monitor displays in full screen the video image from the
alarming channel congured for full screen monitoring. And when the alarm is triggered
simultaneously in several channels, you must congure the auto-switch dwell me.
Steps
1. Go to
Conguraon → System → Live View → General .
2. Set the event output and dwell me.
Alarm Pop-up Output
Select the output to show event video.
Alarm Pop-up Delay
Set the
me in seconds to show alarm event image. If alarms are triggered simultaneously in
several channels, their full-screen images will be switched at an interval of 10 seconds
(default dwell
me).
3. Go to Linkage Acon interface of the alarm detecon.
4. Select Full Screen Monitoring alarm linkage acon.
5. Select the channel(s) in Trigger Channel sengs you want to make full screen monitoring.
Note
Auto-switch will terminate once the alarm stops and back to the live view interface.
Congure Audio Warning
The audio warning enables the video recorder to trigger an audible beep when an alarm is
detected.
Network Video Recorder User Manual
63