6 English
5 Operation
Fitting the side handle
CAUTION
Risk of injury! The depth gauge, if fitted but not used, might hinder the operator.
▶ Remove the depth gauge from the tool.
CAUTION
Risk of injury! Loss of control over the rotary hammer drill.
▶ Check that the side handle is fitted correctly and tightened securely. Check that the
clamping band is engaged in the groove in the tool.
2
TE 2-M
Fitting / removing the chuck
3
Fitting/removing the drill bit or other accessory: SDS chuck
Note
Use of unsuitable grease may cause damage to the product. Use only the
recommended grease supplied by Hilti.
4
TE 2-M
Fitting/removing the drill bit or other accessory: Quick-release chuck
5
Adjusting the depth gauge
Note
Always pay attention to the maximum length of the depth gauge.
6
Drilling with hammering action (hammer drilling)
7
TE 2-S
Light hammering action
7
TE 2
TE 2-S
Drilling
7
TE 2-M
Drilling in first gear or drilling in second gear
7
Forward / reverse
Risk of damage Actuation while the tool is running may result in damage to the gearing.
▶ Do not operate the forward / reverse switch while the motor is running.
8
6 Care and maintenance
WARNING
Danger of electric shock! Carrying out care and maintenance while the supply cord is connected to
the power outlet presents a risk of serious injuries including burns.
▶ Always unplug the supply cord before carrying out all care and maintenance tasks.
Care
• Carefully remove stubborn dirt from the tool.
• Clean the air vents carefully with a dry brush.
• Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
they can attack the plastic parts.
Printed: 04.10.2017 | Doc-Nr: PUB / 5170560 / 000 / 05