3.4 Setting Measurement Range
31
3
Chapter 3 Measurement
This section describes how to set the measurement range for resistance or voltage measurement.
Choose a resistance measurement range from among the following ranges:
• Six ranges, including the 30 mΩ through 3000 Ω ranges (For the BT3561A)
• Seven ranges, including the 3 mΩ through 3000 Ω ranges (For the BT3562 and BT3563)
Choose a voltage measurement range from among the following ranges:
• Two ranges, including the 6 V through 60 V ranges (For the BT3561A, BT3562, and BT3562-01)
• Three ranges, including the 6 V through 100 V ranges (For the BT3562A)
• Three ranges, including the 6 V through 300 V ranges (For the BT3563)
There is also an auto-range function, which determines the optimal range automatically.
3.4 Setting Measurement Range
Resistance measurement range
1
Select the resistance measurement range.
The position of the decimal point and unit of measurement on the display will
be switched according to the selected range.
2
Select the range to use.
lit
m lit
When the 3 range is selected
When the 300 m
range is
selected
Increase the resistance measurement range.
Decrease the resistance measurement range.
Pressing the up or down keys while in auto-range mode will cancel auto-ranging,
leaving the current measurement range as the manually set range.