EasyManua.ls Logo

Hioki IR4052 - User Manual

Hioki IR4052
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
IR4051
IR4052
Instruction Manual
INSULATION TESTER
EN
Sept. 2023 Revised edition 9
IR4051A981-09
Scan this code to watch the
instructional video(s).
Carrier charges may apply.
Video
Read carefully before use.
Keep for future reference.
[600387699]
www.hioki.com/
IR4053
IR4051
IR4052
Instruction Manual
INSULATION TESTER
EN
Sept. 2023 Revised edition 9
IR4051A981-09
Scan this code to watch the
instructional video(s).
Carrier charges may apply.
Video
Read carefully before use.
Keep for future reference.
[600387699]
www.hioki.com/
IR4053
HIOKI IR4051A981-09

Questions and Answers

  • K
    Katrina GonzalezAug 30, 2025
    Why does insulation resistance increase over time on Hioki IR4052?
    • C
      Colin NguyenAug 30, 2025
      If the insulation resistance measured value increases over time on your Hioki Test Equipment, it is not a malfunction. If the measured value fluctuates gradually, wait for it to stabilize and then use that value.
  • P
    Patricia RichardsonAug 29, 2025
    Why does Hioki Test Equipment give different readings for the same target?
    • D
      Dr. Sandra Fields DDSAug 29, 2025
      If you get a different measured value each time you measure the same target with your Hioki Test Equipment, it could be due to the effects of the insulator’s polarity. Allow about 1 hour to 1 day to pass after the first measurement before repeating. Alternatively, the differences may be due to the insulator’s temperature characteristics, so measure the target under the same temperature and humidity conditions.
  • K
    Kathy GonzalesAug 28, 2025
    How to measure in 500 V or 1,000 V range on Hioki Test Equipment?
    • W
      William ElliottAug 28, 2025
      If you are unable to perform a measurement in the 500 V or 1,000 V range on your Hioki Test Equipment, press after setting the rotary selector to the 500 V or 1,000 V range. Note that pressing while holding the MEASURE key will not disable the lock function.
  • T
    teresaloveAug 27, 2025
    What causes excessive variation in measured values on Hioki Test Equipment?
    • S
      sboothAug 27, 2025
      If you experience excessive variation in the measured value with your Hioki Test Equipment, it could be due to induced noise from a nearby charging circuit. Try disconnecting the circuit breaker for any nearby charging circuits. If this isn't possible, use the lowest measured value as your result. Another cause could be a large capacitance component in the measurement target. If possible, remove the capacitor; otherwise, use the lowest measured value.
  • B
    Benjamin HollandAug 27, 2025
    Why do the batteries run out so fast in my Hioki Test Equipment?
    • C
      Corey MitchellAug 27, 2025
      If the batteries in your Hioki Test Equipment run out immediately, replace the nickel-metal-hydride or manganese batteries with alkaline batteries.
  • G
    Gabriel HammondAug 25, 2025
    How to troubleshoot Hioki Test Equipment when unable to perform measurement?
    • M
      Manuel LongAug 26, 2025
      If you are unable to perform a measurement with your Hioki Test Equipment, try turning off the MEASURE key and then pressing it again. Also, make sure to separate the measurement target from all power sources before taking measurements.
  • J
    Jill ArmstrongAug 25, 2025
    What to do if the measured value is the maximum on Hioki IR4052 Test Equipment?
    • J
      jennifer64Aug 25, 2025
      If the measured value is shown as the maximum display value when using Hioki Test Equipment, check the continuity of the test lead with a tester. Also, verify that the test leads are securely connected to both the instrument and the measurement points.

Summary

Overview

1.1 Product Overview

Introduction to the insulation tester and its intended use.

1.3 Names and Functions of Parts

Detailed identification and explanation of instrument controls, display elements, and terminals.

Measurement Procedures

2.1 Measurement Preparations & Inspection

Steps for preparing the instrument, test leads, and performing pre-measurement checks.

2.4 Configuring the Comparator

Setting up the PASS/FAIL judgment function with selectable reference values.

2.5 Insulation Resistance Measurement

Detailed procedure for measuring insulation resistance, including voltage selection and safety.

2.6 Discharging Function

Procedure for safely discharging the test object after measurement to prevent electric shock.

2.7 Voltage Measurement

Instructions for performing AC voltage measurements and checking for live conductors.

2.8 Low Resistance Measurement

Steps for measuring low resistance, including essential zero adjustment.

2.9 PVΩ Measurement IR4053

Procedure for measuring insulation performance of solar panels using the IR4053.

Specifications

Standard Specifications

Details on functions, live circuit indicator, and automatic electric discharge.

General Specifications

Covers accuracy, warranty, operating/storage conditions, IP code, and voltage ratings.

Measurement functions

Specific technical data for Insulation Resistance Measurement, including ranges and accuracy.

Maintenance and Service

4.1 Troubleshooting

Guidance on diagnosing and resolving common instrument issues and error messages.

4.2 Replacing Batteries or Fuse

Step-by-step instructions for replacing batteries and fuses with safety notes.

4.3 Replacing the Pin (Option)

Procedure to replace the tip pin on the optional L9788-10 test lead.

Appendix

Measurement Principles

Explanation of the underlying principles for different measurement types.

Insulation Resistance Measurements for Solar Cell Array

Methods and characteristics for performing insulation resistance tests on solar cell arrays.

Hioki IR4052 Specifications

General IconGeneral
TypeInsulation Tester
CategoryTest Equipment
Test Voltage50V, 125V, 250V, 500V, 1000V
AC Voltage Measurement600V
DC Voltage Measurement600V
DisplayDigital LCD
Power SupplyLR6 (AA) alkaline batteries ×4
Battery LifeApprox. 20 hours (continuous use)
Dimensions159 mm × 177 mm × 53 mm
WeightApprox. 600 g (including batteries)