Instruction Manual
INSULATION TESTER
ST5520-01
INSULATION TESTER
ST5520
Instruction Manual
Aug.2015 Revised edition 2
ST5520A981-02 15-08H
EN

Table of Contents

Questions and Answers

  • M
    Michelle MooreAug 18, 2025
    Why are my Hioki ST5520-01 measured values unstable?
    • C
      Cameron HuntAug 18, 2025
      Unstable measured values may occur if the power frequency setting is not appropriate for your environment. To resolve this, change the power frequency setting to match your local power supply.
  • G
    Gail OlsonAug 20, 2025
    What to do if the key operation cannot be performed on Hioki ST5520-01?
    • J
      jackiekirkAug 20, 2025
      If the key lock function is enabled, disable it. If the interlock function is set to ON, switch it to OFF.
  • A
    Andrew RamirezAug 23, 2025
    How to fix ERR:001 on Hioki Test Equipment?
    • M
      Matthew GarciaAug 23, 2025
      ERR:001 indicates that the upper limit value cannot be set because the lower limit value is greater than the upper limit value. To fix this, set the upper limit value to be greater than the lower limit value.
  • S
    Sharon WilliamsAug 26, 2025
    What to do if Hioki ST5520-01 Test Equipment voltage is not output?
    • P
      Pamela HarrisonAug 26, 2025
      If the voltage is not output, the probe wires may be broken. Use the contact check function or check the probe using a tester to resolve this issue.
  • T
    Tony BridgesAug 28, 2025
    What to do if Hioki ST5520-01 does not turn on?
    • J
      Justin JonesAug 28, 2025
      If the power does not turn on, the power may not be supplied. Check the power cord to ensure it is properly connected.
  • F
    frankrobertAug 30, 2025
    Why is the set voltage not output on my Hioki ST5520-01?
    • S
      Sherry MorenoAug 30, 2025
      If the set voltage is not being output, check the resistance of the load. The measurement current is limited to less than 2.0 mA, and the voltage cannot rise to the set voltage with a load carrying a current of 2.0 mA or more.
  • K
    kevinswansonSep 1, 2025
    Why does a contact check error occur on Hioki ST5520-01?
    • F
      fpearsonSep 2, 2025
      A contact check error may occur if the probe wires are broken. Check the probe using a tester to resolve this.
  • A
    Anthony BakerSep 4, 2025
    Why is the comparator judgment result wrong on my Hioki ST5520-01 Test Equipment?
    • K
      Kelly SalazarSep 4, 2025
      The comparator judgment result may be incorrect if the resistance range is not set appropriately for the lower limit value. Refer to the resistance measurement specifications and change the range accordingly.
  • S
    Stacey JimenezSep 7, 2025
    How to fix ERR:003 on Hioki ST5520-01 Test Equipment?
    • C
      Christina MorseSep 7, 2025
      ERR:003 means that the response time is set longer than the test duration. Check that the parameter range is correct.
  • A
    amy33Sep 9, 2025
    What to do if Hioki Test Equipment control cannot be performed with EXT.I/O?
    • J
      Juan MccartySep 10, 2025
      If control cannot be performed with EXT.I/O, the wiring may be incorrect. Check the input and output signals using the EXT.I/O test function.

Summary

Safety Notes

General Safety Information

Explains hazard levels (DANGER, WARNING, CAUTION), symbols, and measurement categories for safe operation.

Usage and Handling Precautions

Preliminary checks

Perform inspections of probes and instrument operation before first use to ensure safety and detect damage.

Installation and Handling Precautions

Avoid unstable surfaces, do not remove instrument case, and handle with care to prevent damage or injury.

Cord and Lead Handling

Avoid shorting live lines, check cord condition, do not bend excessively, and observe connection precautions.

2 Preparations

Connecting Power and Measurement Leads

Connect the power cord and measurement leads following safety guidelines.

Pre-Operation Inspection

Perform checks on accessories, instrument, and insulation resistance tests before initial use.

3 Basic Settings

Setting Test Voltage and Range

Configure the test voltage (25V-1000V) and resistance measurement range (manual or auto).

Measurement Speed and Duration

Switch between FAST/SLOW measurement speeds and set the test duration.

Judging Measured Values (Comparator Function)

Configure the comparator function for pass/fail criteria and judgment methods.

5 Useful Functions

Contact and Short Circuit Checks

Verify contact integrity and check for short circuits before applying test voltage.

6 Saving and Loading Measurement Conditions

7 External Control (EXT.I;O)

8 Communications (RS-232 C interface)

Automatic Data Export

Configure the instrument to automatically send measured values to a computer after tests.

Controlling Instrument via Commands

Remotely control the instrument and acquire data using communication commands.

Command Reference

Detailed information on communication commands, syntax, parameters, and examples.

9 Specifications

10 Maintenance and Service

Troubleshooting Common Issues

Guidance for resolving common instrument issues before contacting service.

Error Display and Solutions

Lists error messages, their meanings, solutions, and references for troubleshooting.

Hioki ST5520-01 Specifications

General IconGeneral
BrandHioki
ModelST5520-01
CategoryTest Equipment
LanguageEnglish