153
Resistance measurement
Resistance range
composition
Manual range (2 M
Ω
, 20 M
Ω
, 200 M
Ω
, 2000 M
Ω
, 4000 M
Ω
),
Auto range
Range display The set range is displayed at the top of the screen.
Rated
measurement
voltage
Resistance
range
Display
range
Resolution
25 V ≤ V < 100 V
2 M
Ω
range
0.000 M
Ω
to
4.000 M
Ω
0.001 M
Ω
20 M
Ω
range
1.90 M
Ω
to
40.00 M
Ω
0.01 M
Ω
200 M
Ω
range
19.0 M
Ω
to
400.0 M
Ω
0.1 M
Ω
100 V ≤ V < 500 V
2 M
Ω
range
0.000 M
Ω
to
4.000 M
Ω
0.001 M
Ω
20 M
Ω
range
1.90 M
Ω
to
40.00 M
Ω
0.01 M
Ω
200 M
Ω
range
19.0 M
Ω
to
400.0 M
Ω
0.1 M
Ω
2000 M
Ω
range
190 M
Ω
to
4000 M
Ω
1 M
Ω
500 V ≤ V ≤ 1000 V
2 M
Ω
range
0.000 M
Ω
to
4.000 M
Ω
0.001 M
Ω
20 M
Ω
range
1.90 M
Ω
to
40.00 M
Ω
0.01 M
Ω
200 M
Ω
range
19.0 M
Ω
to
400.0 M
Ω
0.1 M
Ω
4000 M
Ω
range
190 M
Ω
to
9990 M
Ω
1 M
Ω
* To display a value of 1000 M
Ω
or over, the last digit is xed at 0 and the
resolution is 10 M
Ω
. When the measured value exceeds the display range,
“Over.F” or “Under.F” is displayed.
10
9
8
7
6
5
4
3
2
1
Appx. Ind.