Error code list
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 43
24 183 19 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
Error Code Error Cause Elimination
• Cable between the central unit
and the sensor unit defective.
• Check the cable to the sensor
unit
• Can bus port in the central unit
defective
• Replace the central unit
• Can bus port in the sensor unit
is defective
• Replace the sensor unit
E62
Error in the can bus data
transfer of the pressure
transducer sensor unit
• Sensor unit is defective • Replace the sensor unit
E63
Error in the can bus
pressure transducer
sensor unit
• The analog values of the
sensor unit are invalid
• Replace the sensor unit
E64
Error in the can bus data
transfer of the
length/angle sensor unit
• See E62 • See E62
E65
Error in the can bus
length/angle sensor unit
• See E63 • See E63
E66
Error in the data of the
digital I/O MENTOR
• PDB variable invalid • Change system software
• Change MENTOR
E67
Error in the can bus data
transfer of the digital I/O
external module
• PDB variable invalid • Connect digital I/O external
CAN module
E68
Error in the can bus data
transfer of the force
sensor unit
• See E62 • See E62
E69
Error in the can bus
force sensor unit
• See E63 • See E63
E84
Wrong rigging condition.
• The selected rigging condition
is not contained in the crane
data file.
• Select another rigging condition
• Check the programming in the
crane data file.
E85
Error in the radius
determination
• The computed radius is too
small (negative deflection)
• Check the programming in the
crane data file.
E89
Operating mode
switchover with load.
• The operating mode on the
console has been switched over
with the boom loaded.
• Select operating mode without
load on the boom
E98
LMI watchdog activated
• LMI processing time limit
exceeded
• Reset system
• Connect PC terminal and watch
error messages
EAB
Short circuit in the A2B
switch circuit
(not with radio A2B)
• Short circuit in the A2B switch
• Short circuit in the cable to the
A2B switch
• Replace A2B switch
• Replace cable to the A2B
switch
EAC
A2B switch circuit
disconnected
(not with radio A2B)
• Disconnected cable in the A2B
switch
• Disconnected cable to the A2B
switch
• Connect or replace cable in the
A2B switch
• Connect or replace cable to the
A2B switch