Error Code Error Cause Elimination
Cable between the central unit
and the sensor unit defective.
Check the cable to the sensor
unit
Can bus port in the central unit
defective
Replace the central unit
Can bus port in the sensor unit
is defective
Replace the sensor unit
E62
Error in the can bus data
transfer of the pressure
transducer sensor unit
Sensor unit is defective Replace the sensor unit
E63
Error in the can bus
pressure transducer
sensor unit
The analog values of the
sensor unit are invalid
Replace the sensor unit
E64
Error in the can bus data
transfer of the
length/angle sensor unit
See E62 See E62
E65
Error in the can bus
length/angle sensor unit
See E63 See E63
E66
Error in the data of the
digital I/O MENTOR
PDB variable invalid Change system software
Change MENTOR
E67
Error in the can bus data
transfer of the digital I/O
external module
PDB variable invalid Connect digital I/O external
CAN module
E68
Error in the can bus data
transfer of the force
sensor unit
See E62 See E62
E69
Error in the can bus
force sensor unit
See E63 See E63
E84
Wrong rigging condition.
The selected rigging condition
is not contained in the crane
data file.
Select another rigging condition
Check the programming in the
crane data file.
E85
Error in the radius
determination
The computed radius is too
small (negative deflection)
Check the programming in the
crane data file.
E89
Operating mode
switchover with load.
The operating mode on the
console has been switched over
with the boom loaded.
Select operating mode without
load on the boom
E98
LMI watchdog activated
LMI processing time limit
exceeded
Reset system
Connect PC terminal and watch
error messages
EAB
Short circuit in the A2B
switch circuit
(not with radio A2B)
Short circuit in the A2B switch
Short circuit in the cable to the
A2B switch
Replace A2B switch
Replace cable to the A2B
switch
EAC
A2B switch circuit
disconnected
(not with radio A2B)
Disconnected cable in the A2B
switch
Disconnected cable to the A2B
switch
Connect or replace cable in the
A2B switch
Connect or replace cable to the
A2B switch

Other manuals for Hirschmann iVISOR mentor QVGA