Protection from Unauthorized Access
Basic Configuration
Release
6.0
07/2010
6.5
HiDiscovery Access
91
Prerequisities for further configuration:
X The port for the LAN connection is enabled and configured correctly (see
on page 73 “Configuring the Ports“)
X Prerequisites for the device to be able to send an alarm (trap) (see on
page 179 “Configuring Traps“):
You have entered at least one recipient
You have set the flag in the “Active” column for at least one recipient
In the “Selection” frame, you have selected “Port Security”
Parameter Value Explanation
Allowed IP Addresses 10.0.1.228
10.0.1.229
The defined users are the device with the
IP address 10.0.1.228 and the device with the
IP address 10.0.1.229
Action portDisable Disable the port with the corresponding entry in the
port configuration table (see on page 73
“Configuring the Ports“) and send an alarm

Table of Contents