EasyManua.ls Logo

Hirschmann MACH 4002 Family - Technical Data; 3.1 General Data

Hirschmann MACH 4002 Family
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
MACH 4002
Release
1.0
10/05
3 Technical data
General data
1)
NEC Class 2 power source safety extra-low voltage (SELV/PELV)
2)
The 0V connectors within a DC module (M4-...-...VDC 300W) are connected to
each other
Dimensions MACH 4002 W x H x D: 480 mm x 88 mm x 435 mm
Assembly MACH 4002
M4-POWER
19" rack
19" rack
Weight MACH 4002 7.5 kg
Voltage supply MACH 4002 M4-S-xx power supply or power unit chassis
M4-POWER with M4-P-xx power supply,
please order separately
Operating voltage M4-S-AC/DC 300W
M4-S-24VDC 300W
M4-S-48VDC 300W
100-240 VAC, 120-350 VDC
24 VDC (19.2 V - 32 V)
1)
48 VDC (38.4 V - 60 V)
1)
M4-P-AC/DC 300W
M4-P-24VDC 300W
M4-P-48VDC 300W
100-240 VAC, 120-350 VDC
24 VDC (19.2 V - 32 V)
1)
48 VDC (38.4 V - 60 V)
1)
Buffer time M4-P-AC/DC 300W
M4-...-24VDC 300W
M4-...-48VDC 300W
1/2 mains period minimum
10 ms at 20.4 VDC minimum
10 ms at 40.8 VDC minimum
Current
consumption
M4-S-AC/DC 300W
M4-S-24VDC 300W
M4-S-48VDC 300W
1.8 A (230 VAC) max., 4.2 A (110 VAC) max.
21.0 A (24 VDC) maximum
10.1 A (48 VDC) maximum
M4-P-AC/DC 300W
M4-P-24VDC 300W
M4-P-48VDC 300W
1.8 A (230 VAC) max., 4.2 A (110 VAC) max.
21.0 A (24 VDC) maximum
10.1 A (48 VDC) maximum
Switch-on current M4-S-AC/DC 300W
M4-P-AC/DC 300W
typ. <40 A at 265 VAC and cold start
typ. <40 A at 265 VAC and cold start
Overload current
protection at input
non-changeable fuse
Potential difference
between input vol-
tage and housing
M4-...-...VDC 300W Potential difference to input voltage
+24 VDC/ +48VDC: 60 VDC
Potential difference to input voltage 0V: 60 VDC
2)
Surrounding Storage temperature
Humidity
Atmospheric pressure
Surrounding air: -25 °C to +70 °C
10% to 95% (non condensing)
up to 2.000 m (795 hPa), higher altitudes on
demand
Operating tempe-
rature
MACH 4002
M4-S-xx
M4-P-xx
M-SFP-xx/xx
M-FAST SFP-xx/xx
M4-AIR
M4-8TP-RJ45
M4-FAST 8-SFP
0°C to 50°C
0°C to 50°C
0°C to 50°C
0°C to 60°C
0°C to 60°C
0°C to 50°C
0°C to 50°C
0°C to 50°C
Pollution degree 2
Protection types Laser protection
Protection types
Class 1 conforming to EN 60825-1 (2001)
IP 20

Related product manuals