MACH 4002
Release
1.0
10/05
31
2.3 Carrying out basic settings
IP addresses must be entered when the device is installed for the first time.
The device provides 6 options for configuring the IP addresses:
D Entry via the V.24 connection.
D Entry by HiDiscovery protocol
D Configuration via BOOTP
D Configuration via DHCP
D Configuration via DHCP Option 82
D The AutoConfiguration Adapter
U State of delivery
D IP address: The device looks for the IP address using DHCP
D Password for management:
user, password: public (read only)
admin, password: private (read and write)
D V.24 data rate: 9.600 baud
D Ring redundancy: off
D ETHERNET ports: Link status is not evaluated (signal contact)
D Optical 100 Mbit ports: 100 Mbit full duplex
All other ports: autonegotiation
D Redundancy manager switched off
D Stand-by coupling off
U USB interface
The USB socket offers an interface for the local connection of an Auto-
Configuration Adapter ACA 21-USB. It is a device for saving/loading the
configuration and for loading the software.
Pin number Signal name
1 VCC
2 - Data
3 + Data
4 Ground