Troubleshooting
Regarding the indicator lamps (continued)
POWER
indicator
LAMP
indicator
TEMP
indicator
Description
Blinking
In Red
or
Lighting
In Red
Turned
off
Blinking
In Red
The cooling fan is not operating.
Please turn the power off, and allow the projector to
cool down at least 20 minutes. After the projector has
sufciently cooled down, please make conrmation
that no foreign matter has become caught in the fan,
etc., and then turn the power on again.
If the same indication is displayed after the remedy,
please contact your dealer or service company.
Blinking
In Red
or
Lighting
In Red
Turned
off
Lighting
In Red
There is a possibility that the interior portion
has become heated.
Please turn the power off, and allow the projector to
cool down at least 20 minutes. After the projector has
sufciently cooled down, please make conrmation of
the following items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air lter dirty?
• Does the peripheral temperature exceed 45°C?
If you use CP-X8150, CP-WX8240, CP-SX8350
or CP-WU8440, does the peripheral temperature
exceed 40°C?
• Is the setting for ALTITUDE appropriate?
For details on ALTITUDE, refer to ALTITUDE
of SERVICE in the OPTION menu (
67). If the
projector is used with a wrong setting, it may cause
damage to the projector itself or the parts inside.
Lighting
In Green
Simultaneous
blinking in Red
It is time to clean the air lter.
Please immediately turn the power off, and clean or
change the air lter referring to the section Cleaning
and replacing the air lter. After cleaning or
changing the air lter, please be sure to reset the
lter timer. After the remedy, reset the power to ON.
Lighting
In Green
Alternative
blinking in Red
There is a possibility that the interior portion
has become overcooled.
Please use the unit within the usage temperature
parameters (0°C to 40°C or 45°C (
User's Manual
(concise))). After the treatment, reset the power to
ON.
Blinking In
Green for
approx. 3
seconds.
Turned
off
Turned
off
At least 1 Power ON schedule is saved to the
projector.
Please refer to 3.1.7 Schedule Settings in the
Network Guide.
(continued on next page)

Table of Contents

Other manuals for Hitachi CP-WU8450

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi CP-WU8450 and is the answer not in the manual?

Hitachi CP-WU8450 Specifications

General IconGeneral
Matrix size0.76 \
Matrix type3-panel (p-Si TFT active)
Native aspect ratio16:10
Projection distance1 - 38.3 m
Projection technologyLCD
Contrast ratio (typical)3000:1
Screen size compatibility30 - 600 \
Projector native resolutionWUXGA (1920x1200)
Audio input3
RS-232 ports1
Zoom capabilityYes
Focal length range- mm
Lamp typeUHP
Lamp power330 W
Lamps quantity1 lamp(s)
Light source typeLamp
Service life of light source- h
3D-
Supported video modes1080i, 1080p, 480i, 480p, 576i, 576p, 720p
Analog signal format systemNTSC, NTSC 4.43, PAL, PAL 60, PAL M, PAL N, SECAM
Supported graphics resolutions1024 x 768 (XGA), 1280 x 1024 (SXGA), 1360 x 768 (WXGA), 1400 x 1050 (SXGA+), 1440 x 900 (WXGA+), 1600 x 1200 (UXGA), 640 x 480 (VGA), 800 x 600 (SVGA)
RMS rated power16 W
Number of built-in speakers2
DVI portNo
BNC input ports5
USB connector typeUSB Type-A, USB Type-B
Serial interface typeRS-232
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
USB 3.2 Gen 1 (3.1 Gen 1) Type-A ports quantity0
Noise level- dB
CertificationUL/cUL, FCC Part15 class A, AS/NZS CISPR22 class A, CE, GOST-R
PlacementDesktop, Ceiling
Product typeStandard throw projector
Product colorWhite
Power sourceAC
AC input voltage100 - 240 V
Power consumption (standby)- W
Operating temperature (T-T)0 - 45 °C
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth396 mm
Width498 mm
Height135 mm
Weight8700 g

Related product manuals