6 - 31
Table 6-4-1 Value of Red Level/Vector
Fig. 6-4-5 When using a vectorscope
Fig. 6-4-6 When using an oscilloscope
Adjustment > Adjustment Procedure
7) Click the GAIN UP or GAIN DOWN button
in ROUGH ADJUSTMENT box so that the
value of red vector or red level approaches
that in Table 6-4-1. Click the button at
approx. 2-second intervals while checking
the increase or decrease of vector or level.
8) Click the GAIN UP or GAIN DOWN button
in FINE ADJUSTMENT box so that the
value of red vector or red level matches that
in Table 6-4-1. Click the button at approx.
2-second intervals while checking any
increase or decrease in vector or level.
9) After step 8) is complete, be sure to click the
SAVE button.
Note that clicking the RETURN button will
restore the ADJUST MENU screen to the
status before the adjustment was performed.
10) Click the OK button in dialog to restore the
ADJUST MENU screen.
11) Press the MENU button on DVD video
camera/recorder, and use the / /
/ / to specify (return to) “White Bal.:
Auto”.
RED
BURST
100%
A
B
RED
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
SAVE
RETURN
CHROMA GAIN ADJUSTMENT
ROUGH ADJUSTMENT
FINE ADJUSTMENT
GAIN UP
GAIN DOWN
GAIN UP
GAIN DOWN
CONNECTION
7
8
9
CHROMA GAIN ADJUSTMENT screen
ADJUSTMENT FINISHED dialog
FINISHED
ADJUSTMENT FINISHED.
OK
10
Model When using a
vectorscope
When using an
oscilloscope
DZ-GX5080A
A = 240 %
± 5 %
B = 690mV
± 20 mVp-p
DZ-GX5020A
DZ-GX5000A

Table of Contents