Hitachi hard disk drive specifications
220
Status Flag Definitions
An Attribute Value less than or equal to its corresponding Attribute Threshold indicates an
advisory condition where the usage or age of the device has exceeded its intended design
life period.
An Attribute Value less than or equal to its corresponding attribute threshold indicates a
pre-Failure condition where imminent loss of data is being predicted.
The Attribute Value is updated only during Off-Line testing
The Attribute Value is updated during On-Line testing or during both On-Line and Off-Line
testing.
Normalized Values: The device will perform conversion of the raw Attribute Values to transform them into
normalized values, which the host can then compare with the Threshold values. A Threshold is the excursion
limit for a normalized Attribute Value.
11.43.2.3 Off-Line Data Collection Status
The value of this byte defines the current status of the off-line activities of the device. Bit 7 indicates Automatic
Off-Line Data Collection Status.
Automatic Off-Line Data Collection Status
Automatic Off-Line Data Collection is disabled.
Automatic Off-Line Data Collection is enabled.
Bits 0 thru 6 represents a hexadecimal status value reported by the device.
Off-line data collection never started
All segments completed without errors.
Off-line data collection suspended by interrupting command
Off-line data collecting aborted by interrupting command
Off-line data collection aborted with fatal error