Hitachi hard disk drive specifications
263
12 Timings
The timing of BSY and DRQ in Status Register are shown in Table 180Table 181.
The other timings are described in HDS7230xxBLA642 / HDS5C30xxALA632 / HCS5C20xxALA632 Final
Functional Specification.
Device Busy after Power On
The device sets BSY(=0) and
RDY(=1) to the Status
Register and sends a Register
FIS to the host.
Device Busy after Software
Reset
The host asserts SRST(=1)
in the Device Control
Register and sends a
Register FIS to the Device.
The Host sets BSY(=1) to the
Status Register.
Device Ready after
Software Reset
The host asserts SRST(=1)
to the Device Control
Register and sends a
Register FIS to the Device.
Then the host negates
SRST(=0) to the Device
Control Register and sends a
Register FIS to the Device.
The device sets BSY(=0) and
RDY(=1) to the Status
Register and requests to send
a Register FIS to the host.
Device Ready after
COMRESET
The device sets BSY(=0) and
RDY(=1) to the Status
Register and sends a Register
FIS to the Host.
Device Busy after a Register
FIS to issue a command
The host sets proper values
in the registers and sends a
Register FIS
The host sets BSY(=1) to the
Status register
A Register FIS to report
Command Complete
The host sets BSY(=1) to the
Status Register
The device sets the status of
the command to the Status
Register and sends a Register
FIS to the host
Device Busy after a Register
FIS to issue a command
The host sets proper values
in the registers and sends a
Register FIS
The host sets BSY(=1) to the
Status Register
PIO SETUP FIS for data-in
transfer
The host sets BSY(=1) to the
Status Register
The device sets BSY(=0) and
DRQ(=1) to the Status
Register and sends a PIO
SETUP FIS to the host.
Device Busy after data-in
transfer
A PIO SETUP FIS is
transferred to the host.
The host sets BSY(=1) to the
Status Register
Device Busy after a Register
FIS to issue a command
The host sets proper values
in the registers and sends a
Register FIS
The host sets BSY(=1) to the
Status Register
Device Busy after data-out
transfer
The host sends a Data FIS to
the device.
The host sets BSY(=1) to the
Status Register
PIO SETUP FIS for data-out
transfer
The host sets BSY(=1) to the
Status Register
The device sets BSY(=0) and
DRQ(=1) to the Status
Register and sends a PIO
SETUP FIS to the host.
Table 180 Timeout Values