107
(3) Inverter Part of Outdoor Unit PCB
Detail of Check Points
AC-N
AC-L
L-COM
L1
L2
U
V
W
FU3
PCN30
PCN8
CN42
N
P
AC-L1
LED5
Check whether the high voltage still exists in the inverter PCB after power is disconnected. When the unit
is operated, LED5 is turned ON. At the time of powering off the unit, LED5 is turned OFF. In this case, the
residual voltage is less than DC50V.
If LED5 is turned ON while powering off the unit, please wait for about ve minutes, LED5 will turn OFF.
CAUTION
!
TROUBLESHOOTING