EasyManua.ls Logo

Hitachi RPK-1.0FSNSM3 - Page 11

Hitachi RPK-1.0FSNSM3
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P5415078-rev.3
5
l
Do not step on the product nor put any material on it.
l
Do not put any foreign material on the unit or inside the unit.
l
Do not turn OFF the main power source of the indoor unit during the season of heating and cooling.
The water can not be discharged forcedly so that overows from the drain pan.
As the result, the oor and the ceiling surface are smudged.
l
Hold the air lter and the air inlet grille by hand when attaching (removing).
If not, it may cause falling or injury.
l
Do not blow cold air to a person for a long time or overcool.
It may cause deterioration of physical condition and health impairment.
l
Do not install the indoor unit, outdoor unit, remote control switch and cable within approximately 3 meters
from strong electromagnetic wave radiators such as medical equipment.
l
Supply electrical power to the system to energize the crankcase heater for 12 hours before startup after a
long shutdown.
l
Make sure that the outdoor unit is not covered with snow or ice, before operation.
l
The packaged air conditioner may not be operated normally under the following cases.
* In case that electrical power for the packaged air conditioner is supplied from the same power
transformer as the device with high electricity consumption*.
* In case that the power source wires for the device* and for the packaged air conditioner are located
close to each other.
Device*: (Ex) Lift, container crane, rectier for electric railway, inverter power device, arc furnace,
electric furnace, large-sized induction motor and large-sized switch.
Regarding the cases mentioned above, surge voltage may be inducted in the power supply wiring for the
packaged air conditioner due to a rapid change in power consumption of the device and an activation of
switch.
Therefore, check the eld regulations and standards before performing electrical work in order to protect
the power supply for the packaged air conditioner.
l
Do not install the unit in the place where the air ow directly catches to animals or plants.
It could be the cause of adverse affect to animals or plants.
l
It is recommended that the room be ventilated every 3 to 4 hours.
l
The heating capacity of the heat pump unit decreases according to the outdoor air temperature. Therefore,
it is recommended that auxiliary heating equipment be used in the eld when the units is installed in a low
temperature region.
NOTICE
NOTE
CAUTION

Table of Contents