Adjusting Vertical Blade
The vertical blade can adjust with moving by
hand as shown in the gures blow.
RPK-1.0 and 1.5
RPK-2.0 to 4.0
l
Automatic Setting of Louver
The swing louver is stopped and moved by
controlling the remote control switch.
When “Stop” switch is pressed from the
remote control switch, the swing louver will
be closed automatically and the operation is
stopped.
RPK-1.0 and 1.5
RPK-2.0 to 4.0
l
Louver Angle during Cooling and
Dry Operation
The louver angle changes automatically during
the cooling and dry operation to prevent
dew condensation. In order to prevent dew
condensation, the unit operates with its louver
at a different angle from the original setting
for a certain period of time. Even in this case,
LCD of remote control switch displays the set
louver angle.
l
Louver Angle during Heating Operation
The louver angle changes automatically
during the heating operation.
* When the heating operation starts
* When the defrost operation starts
The louver angle is xed to 15
o
.
When the discharge temperature is higher
than 30
o
C, the louver angle automatically
returns to the setting condition.
Do not move the louver by hand. If moved, the
louver mechanism will be damaged and the air ow
direction may not be set.
RPK-1.0 and 1.5
RPK-2.0 to 4.0