22
A057 DC braking force for starting 0.
A058 DC braking time for starting 0.0
A059 DC braking carrier frequency setting 3.0
A061/
A261
Frequency upper limit setting 0.00
A062/
A262
Frequency lower limit setting 0.00
A063
A065
A067
Jump (center) frequency setting 0.00
A064
A066
A068
Jump (hysteresis) frequency width setting 0.50
A069 Acceleration pause frequency setting 0.00
A070 Acceleration pause time setting 0.0
A071 PID Enable
• 00 PID operation OFF
• 01 PID operation ON
00
A072 PID proportional gain 1.0
A073 PID integral time constant 1.0
A074 PID derivative time constant 0.0
A075 PV scale conversion 1.00
A076 PV source setting:
• 00 [OI] terminal (current input)
• 01 [O] terminal (voltage input)
00
A081 AVR function select
• 00 AVR enabled • 01 AVR disabled
• 02 AVR enabled except during decel
00
A082 AVR voltage select 230/230/200
400/460/400
A085 Operation mode selection
• 00 Normal operation
• 01 Energy-saver operation
• 02 Optimal accel/decel operation
00
A086 Energy saving mode tuning 50.0
A092/
A292/
A392
Acceleration (2) time setting 15.0
Func.
Code
Name / Description
Default
Value
–FE/ FU/FR
Set
Value