Functional and Operational Characteristics
2–9
Hitachi VSP User and Reference Guide
• Table 2-2 Mode 269: Storage Navigator Operations on page 2-54 
specifies the details for mode 269 for Storage Navigator operations.
• Table 2-3 Mode 269: SVP Operations on page 2-54 specifies the details 
of mode 269 for SVP operations. 
The following tables were up to date at the time this manual was published. 
However, the system option mode information may change in firmware 
releases that may happen before the next release of this manual. Contact 
Hitachi Data Systems support for the latest information on the Virtual 
Storage Platform system option modes.
The system option mode information includes:
• Mode: Specifies the system option mode number.
• Category: Indicates the functions to which the mode applies.
• Description: Describes the action or function that the mode provides.
• Default: Specifies the default setting (ON or OFF) for the mode.
• MCU/RCU: For remote functions, indicates whether the mode applies to 
the main control unit (MCU) and/or the remote control unit (RCU).
Table 2-1 System option modes
Mode Category Description Default MCU/RCU
20 Public
 (Optional)
R-VOL read only function. OFF MCU
22 Common Regarding the correction copy or the drive copy, in 
case ECCs/LRC PINs are set on the track of copy 
source HDD, mode 22 can be used to interrupt the 
copy processing (default) or to create ECCs/LRC 
PINs on the track of copy target HDD to continue 
the processing.
Mode 22 = ON:
If ECCs/LRC PINs (up to 16) have been set on the 
track of copy source HDD, ECCs/LRC PINs (up to 
16) will be created on the track of copy target HDD 
so that the copy processing will continue. 
If 17 or more ECCs/LRC PINs are created, the 
corresponding copy processing will be interrupted.
Mode 22 = OFF (default)
If ECCs/LRC PINs have been set on the track of copy 
source HDD, the copy processing will be 
interrupted. (first recover ECCs/LRC PINs by using 
the PIN recovery flow, and then perform the 
correction copy or the drive copy again)
One of the controlling option for correction/drive 
copy.
OFF
36 HRC Sets default function (CRIT=Y) option for SVP panel 
(HRC).
OFF MCU