Functional and Operational Characteristics
2–25
Hitachi VSP User and Reference Guide
598 Universal
Replicator for
Mainframe
This mode is used to report SIMs (RC=DCE0 to
DCE3) to a Mainframe host to warn that a URz
journal is full.
Mode 598 = ON:
SIMs (RC=DCE0 to DEC3) to warn that a JNL is full
are reported to SVP and the host.
Mode 598= OFF (default):
SIMs (RC=DCE0 to DEC3) to warn that a JNL is full
are reported to SVP only.
Notes:
1. This mode is applied if SIMs (RC=DCE0 to
DCE3) need to be reported to a Mainframe host.
2. The SIMs are not reported to the Open server.
3. SIMs for JNL full (RC=DCE0 and DCE1) on MCU
are reported to the host connected with MCU.
4. SIMs for JNL full (RC=DCE2 and DCE3) on RCU
are reported to the host connected with RCU.
ON .
676 Audit Log This option is used to set whether an audit log is to
be stored onto the system disk or not.
Mode 676 = ON:
An audit log is stored onto the system disk.
Mode 676 = OFF (default):
An audit log is not stored onto the system disk.
This mode is also enabled/disabled by enabling/
disabling Audit Log Buffer on the [Audit Log
Setting...] window, which can be opened by
selecting [Settings] -> [Security] -> [Audit Log
Setting...] on Storage Navigator.
Notes:
1. 1. This option is applied to the sites where the
level of importance of an audit log is high.
2. A system disk with available space of more
than 130 MB (185 cylinders when the track
format is 3380/6586/NF80, and 154 cylinders
when the track format is 3390/6588) must
exist. (Otherwise, audit log is not stored even
this option is ON).
3. Make sure to turn this option on after preparing
a normal system disk that meets the condition
in (2). If Define Configuration & Install is
performed, turn this option on after formatting
the system disk.
OFF .
Mode Category Description Default MCU/RCU