30
PMML0600 rev.0 - 06/2022
3
CONSIDERATIONS
ELECTRICAL DATA
3.1.3.2 YUTAKI H Combi
HWD-WE-220S(-K)
Model Power supply
Applicable
voltage
Operation mode
RNC
(A)
IPT
(kW)
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
HWD-WE-220S(-K)
~ 230V 50Hz 253 207
Without electric heater 1.4 0.18 1.47 0.18
With electric heater 27.6 6.18 27.6 6.18
With DHW tank heater 13.4 2.93 13.4 2.93
With DHW tank heater and
electric heaters
39.5 8.93 39.5 8.93
3N~ 400V
50Hz
440 360
Without electric heater 1.4 0.18 1.47 0.18
With electric heater 17.4 6.18 18.9 6.18
With DHW tank heater 13.4 2.93 13.4 2.93
With DHW tank heater and
electric heaters
17.4 8.93 18.9 8.93