66
PMML0600 rev.0 - 06/2022
6
OPTIONAL UNIT WIRING FOR ACCESSORIES
ELECTRICAL AND CONTROL SETTINGS
6.1  Optional unit wiring for accessories
6.1.1  Summary of the terminal board connections
RASM-(2-3)VRE, RASM-(4-7)(V)R(W)1E and HWM-WE
TERMINAL BOARD 1 (TB1)
~ 230V 50Hz
Main power supply connection
-
TERMINAL BOARD 2 (TB2)
H-LINK communication
The H-LINK transmission has to be done between the indoor unit and the 
terminals 1-2 of either outdoor unit, ATW-RTU or any other central device.
H-LINK communication for 
Terminals for the connection of the YUTAKI unit controller.
5 DHW tank’s thermistor
The DHW sensor is used to control the temperature of the domestic hot 
water tank.
Common terminal for thermistor.
7
Thermistor for water outlet 
temperature of second cycle
The sensor is used for the second temperature control and should be 
positioned aer the mixing valve and the circulation pump.
8
Thermistor for water outlet 
temperature of third cycle
The sensor is used for the third temperature control and should be 
positioned aer the hydraulic separator, buer tank or boiler combination.
Common terminal for thermistors.
10
Thermistor for swimming pool 
water temperature
The sensor is used for the swimming pool temperature control and should 
be positioned inside plate heat exchanger of the swimming pool.
11
Thermistor for second ambient 
temperature
The sensor is used for the second ambient temperature control and it 
should be positioned outdoors.
Earth connection for the 3 way valve and water pump.
Terminal Line common for input 1 and input 2.
14 Input 1 (Demand ON/OFF) (*)
The air to water heat pump system has been designed to allow the 
connection of a remote thermostat to eectively control your home’s 
temperature. Depending on the room temperature, the thermostat will turn 
the air to water heat pump system ON and OFF. 
15 Input 2 (ECO mode) (*)
Available signal which allows to reduce the water setting temperature of 
circuit 1, circuit 2 or both.
Terminal Line common for inputs 3, 4, 5, 6, 7.
17 Input 3 (Swimming pool) (*)
Only for swimming pool installations: It is necessary to connect an external 
input to the air to water heat pump to provide signal when the water pump