OPTIONAL UNIT WIRING FOR ACCESSORIES
ELECTRICAL AND CONTROL SETTINGS
HWD-WE-220S(-K)
TERMINAL BOARD 1 (TB1)
~ 230V 50Hz
Main power supply connection
-
TERMINAL BOARD 2 (TB2)
H-LINK communication
The H-LINK transmission has to be done between the indoor unit and the
terminals 1-2 of either outdoor unit, ATW-RTU or any other central device.
H-LINK communication for
Terminals for the connection of the YUTAKI unit controller.
Earth connection for accessories.
Common terminal for thermistor.
7
Thermistor for water outlet
temperature of second cycle
The sensor is used for the second temperature control and should be
positioned aer the mixing valve and the circulation pump.
8
Thermistor for water outlet
temperature of third cycle
The sensor is used for the third temperature control and should be
positioned aer the hydraulic separator, buer tank or boiler combination.
Common terminal for thermistors.
10
Thermistor for swimming pool
The sensor is used for the swimming pool temperature control and should
be positioned inside plate heat exchanger of the swimming pool.
11
Thermistor for second ambient
temperature
The sensor is used for the second ambient temperature control and it
should be positioned outdoors.
Earth connection for the 3 way valve and water pump.
Terminal Line common for input 1 and input 2.
14 Input 1 (Demand ON/OFF) (*)
The air to water heat pump system has been designed to allow the
connection of a remote thermostat to eectively control your home’s
temperature. Depending on the room temperature, the thermostat will turn
the air to water heat pump system ON and OFF.
15 Input 2 (ECO mode) (*)
Available signal which allows to reduce the water setting temperature of
circuit 1, circuit 2 or both.
Terminal Line common for inputs 3, 4, 5, 6, 7.
17 Input 3 (Swimming pool) (*)
Only for swimming pool installations: It is necessary to connect an external
input to the air to water heat pump to provide signal when the water pump
Available input for Solar combination with Domestic Hot Water Tank.
19 Input 5 (Smart function) (*)
For the connection of an external tari switch device to switch OFF the heat
pump during peak electricity demand period. Depending on the setting,
the heat pump or DHWT will be blocked when signal is open/closed.
20 Input 6 (DHW boost) (*)
Available input for an instantaneous heating of the domestic hot water of