3. General data
TCGB0075 rev.0 - 11/2012
57
3
3.2  Outdoor unit
3.2.1  RAS-(4-6)HVRNME-AF
Model RAS-4HVRNME-AF RAS-5HVRNME-AF RAS-6HVRNME-AF
Electrical power supply 1~ 230V 50Hz
Color (Munsell code) - Natural gray (1.0Y8.5/0.5)
Sound pressure level dB(A) 46 48 50
Sound power level dB(A) 65 67 69
Outside mea-
surements
Height mm 1,380 1,380 1,380
Width mm 950 950 950
Depth mm 370 370 370
Net weight kg 103 104 104
Refrigerant  - R-410A
Flow control - Microprocessor-controlled expansion valve
Compressor - DC inverter driven
Quantity - 1 1 1
Power kW 1.80 2.50 2.50
Heat exchanger - Multi-pass cross-nned tube
Outdoor fan - Propeller fan
Quantity - 2 2 2
Air ow rate m³/min 80 90 100
Power  W 70+70 70+70 70+70
Refrigerant pipe connection - Flare-nut connection (factory supplied)
Size
Liquid piping
mm  
(in)
Ø9.53  
(3/8”)
Ø9.53  
(3/8”)
Ø9.53  
(3/8”)
Gas piping
mm  
(in)
Ø15.88  
(5/8”)
Ø15.88  
(5/8”)
Ø15.88  
(5/8”)
Refrigerant charge kg 3.90 4.00 4.00
Maximum current A 18.0 23.0 23.0
Packaging measurements m³ 0.70 0.70 0.70
N O T E
The sound pressure level is based on following conditions: 
• 1meterfromthefrontalsurfaceoftheunit;1.5metersfromoorlevel.
• Voltage of the power source is 230V. 
Theabovedataismeasuredinananechoicchamber,soreectedsoundshouldbetakenintoconsideration
when installing the unit.