5. Install cap (3) after refilling DEF/AdBlue®. Close the tank
cover and lock it with the key.
IMPORTANT:
Do not get on top of DEF/AdBlue® tank (2) or sensors
and piping on the tank. Failure to do so may damage
the machine.
If it becomes necessary to refill DEF/AdBlue® when
cap (3) can not be removed due to freezing, use
emergency filler port (5).
White deposits may be observed when DEF/AdBlue®
is dried naturally; it is normal. Wash out DEF/AdBlue®
deposits with soft water. Never use a high pressure
washer.
f
NOTE:
 Wipe spilled DEF/AdBlue® and wash spilled area with plenty
of water.

The sound of flowing water may be heard from the tank
after the engine stops. It is the sound of returning DEF/
AdBlue® from piping to the tank, not a malfunction.

DEF/AdBlue® will freeze at low temperature, and
deteriorate (ammonification) at high temperature. Store
DEF/AdBlue® at temperature between -10 and 40°C.

Use dedicated container (purchased container) to store or
carry DEF/AdBlue®. Alternatively use a polyethylene resin
tank, or stainless steel tank.
F Line
F
Float
Level Gauge
4
MDC1-07-053
MDAT-07-044
MDAT-07-045
3
5
4
3 2
2 4
ZX225USLC-6
ZX135US-6
ZX135US-6
MDAT-07-046
5
MDD5-07-037
25
4 3
ZX345USLC-6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi ZAXIS 135US-6 class and is the answer not in the manual?

Hitachi ZAXIS 135US-6 class Specifications

General IconGeneral
BrandHitachi
ModelZAXIS 135US-6 class
CategoryExcavators
LanguageEnglish

Related product manuals