7. Electrical Installations
71
• Unclampthebatterycircuitbreakeriftheancillarybatteryisnot
beingusedforalongerperiodoftime(4weeksormore).The
standbycurrentusedcontinuouslybysomeelectricaldevices
discharges the ancillary battery. Even if the battery circuit brea-
kerisinterrupted,thebatterycanstillbechargedbythebattery
charger(conservationcharging).
• Shouldtheconsumerbatteryberemoved,isolatethepluspole
(topreventshortcircuitswhenturningonthemotor).
Battery charger
• Thecharger’scapacityis360W.
• ThechargerfunctionsinaccordancewithIU0U1charging
technology.
• Inthecaseofmisusetheguaranteeandmanufacturer’sliability
willnolongerapply.
• TheairventsintheFIATseatconsolepanelmustnotbecove-
reduporclosed.Ensurethatthereissucientventilation.
Tank probes
Theprobewithrodsmeasuresthecontentsofthefreshand
wastewatertanks.
• Toavoidincrustations,particularlyinthewastewatertank,
neverletthewaterinthetanksstandfortoolong.
• Flushthetanksregularly.
230V automatic circuit breaker with an earth leakage circuit
breaker
The230Vautomaticcircuitbreakersuppliesandprotectsthe
230Vdevices.
• Toswitchothe230Vpowersupplyintheentiresystem,set
the230Vautomaticcircuitbreakerto“0”(OFF).
Fuses
• Onlyreplacedefectivefusesafterthecauseofthedefecthas
beenremediedbyaprofessionalelectrician.
• Thenewfusemusthavethesameamperageastheoldone.