8.2.2 General setup 2/3
Decreases the value
Increases the value
Confirms the default parameters
Goes back to the setup screen 1/3
Goes to the setup screen 3/3
Return to main screen
Static unbalace always present: enables/disables temporary display of the unbalance on the correction
planes selected and the STATIC unbalance
Wheel locking: enables/disables wheel locking in the correction position
Wheel runout: enables/disables wheel eccentricity measurement
Rim runout: enables/disables rim eccentricity measurement
Runout diagnosis: enables/disables display of the runout values on the unbalance
measurement screen
Lift: enables/disables the lift.
Selecting ON+HELP, online help is enabled on the measurement screen,
created with the aim of helping the user to properly use the lift.
Printer: enables/disables the printer
Tyre set: enables/disables the tyre set function
Default parameter setting: resets the default machine settings