Electrical Specications
Electrical Outputs
Power Supply
L Mains supply: This unit runs off a 240
volt 50 hertz single phase outlet
L The controller draws 30 watt at 240VAC
L The internal transformer reduces the 240VAC
to an extra low voltage supply of 24VAC
L The internal transformer is fully compliant
with AS/NZS 61558-2-6 and has been
independently tested and judged to comply
L This unit has a 1.25AMP low energy, high efficient
toroidal transformer for long life performance
Electrical Power Supply:
L Input 24 volts 50/60Hz
Electrical Outputs:
L Maximum of 1.0 amp
To Solenoid Valves:
L 24VAC 50/60Hz 0.75 amps max
Up to 2 valves per station on the inbuilt model
To the Master Valve/Pump Start:
L 24VAC 0.25 amps max
Transformer and fuse capacity must be
compatible with output requirements
Overload Protection
L Standard 20mm M-205 1 amp fast blow glass
fuse, protects against power surges and electronic
fuse rated to 1AMP protects against field faults
L Faulty station skip function
Power Failure
L The controller has permanent memory and
real time clock, so the data is always backed
up even with the absence of all power
L The unit is factory fitted with a 3V CR2032 lithium
battery with up to 10 years memory backup
L The 9V alkaline battery maintains the data
during power outages, and is recommended to
help maintain the life of the lithium battery
Tampering with the unit will void the warranty
The batteries do not run the outputs. The internal
transformer requires mains power to run the valves
Wiring
Output circuits should be installed and protected
in accordance with wiring code for your location
PRO469 Manual 2021 v1.indd 17PRO469 Manual 2021 v1.indd 17 15/1/21 9:40 am15/1/21 9:40 am