Page #45 background imageLoading...
Page #45 background image
3800g/3800gHD/3800gPDF User’s Guide 3 - 9
Discard
This exits without saving any Output Sequence changes.
Output Sequence Editor
Require Output Sequence
When an output sequence is
Required
, all output data must conform to an
edited sequence or the imager will not transmit the output data to the host
device. When it’s
On/Not Required
, the imager will attempt to get the output
data to conform to an edited sequence, but if it cannot, the imager transmits all
output data to the host device as is.
When the output sequence is
Off
, the bar code data is output to the host as the
imager decodes it.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Enter Sequence
Default Sequence
Required
On/Not Required
* Off

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 3800g and is the answer not in the manual?

Honeywell 3800g Specifications

General IconGeneral
Scan speed270 sec/page
Wavelength630 nm
Decoding standardsCodabar Code 3 Interleaved 2 Matrix 2 Code 11, 93, 128 UPC, EAN/JAN GS1 GTIN ISBT 128
Dimensions (WxDxH)79 x 112 x 150 mm
Standard interfacesRS-232
Input voltage5 V
Power consumption235 mA
CertificationIEC60950-1, IEC60825-1 Class 1, FCC Part 15 Class B, UL, cUL, ICES-003 Class B, CE 2004/108/EC EMC, EN55022 Class B, EN55024, EN61000-3-2, EN61000-3-3. 2006/95/EC, GS, NOM-NYCE, MIC Class A, BSMI, C-Tick
Product colorBeige
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight158.8 g