EasyManuals Logo

Honeywell 3800g User Manual

Honeywell 3800g
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
3800g/3800gHD/3800gPDF User’s Guide 3 - 11
To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of the
length. If you use the example on page 3-10, but assume a <CR> suffix and
specific code lengths, you would use the following command line:
SEQBLK62001241FF6A001342FF69001243FF
The breakdown of the command line is shown below:
SEQBLK sequence editor start command
62 code identifier for Code 39
0012 A - Code 39 sample length (11) plus CR suffix (1) = 12
41 start character match for Code 39, 41h = “A”
FF termination string for first code
6A code identifier for Code 128
0013 B - Code 128 sample length (12) plus CR suffix (1) = 13
42 start character match for Code 128, 42h = “B”
FF termination string for second code
69 code identifier for Code 93
0012 C - Code 93 sample length (11) plus CR suffix (1) = 12
43 start character match for Code 93, 43h = “C”
FF termination string for third code
Output Sequence Editor
Require Output Sequence
When an output sequence is
Required
, all output data must conform to an
edited sequence or the image scanner will not transmit the output data to the
host device. When it’s
On/Not Required
, the image scanner will attempt to get
the output data to conform to an edited sequence, but if it cannot, the image
scanner transmits all output data to the host device as is.
Enter Sequence
Default Sequence

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 3800g and is the answer not in the manual?

Honeywell 3800g Specifications

General IconGeneral
Scan speed270 sec/page
Wavelength630 nm
Decoding standardsCodabar Code 3 Interleaved 2 Matrix 2 Code 11, 93, 128 UPC, EAN/JAN GS1 GTIN ISBT 128
Dimensions (WxDxH)79 x 112 x 150 mm
Standard interfacesRS-232
Input voltage5 V
Power consumption235 mA
CertificationIEC60950-1, IEC60825-1 Class 1, FCC Part 15 Class B, UL, cUL, ICES-003 Class B, CE 2004/108/EC EMC, EN55022 Class B, EN55024, EN61000-3-2, EN61000-3-3. 2006/95/EC, GS, NOM-NYCE, MIC Class A, BSMI, C-Tick
Product colorBeige
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight158.8 g