12 - 10
LED Power
Level
Off
PWRLDC0
3-10
Low (50%)
PWRLDC50
3-10
*High (100%)
PWRLDC100
3-10
Illumination
Lights
*Lights On
SCNLED1
3-10
Lights Off
SCNLED0
3-10
Imager Time-
Out
Range 0 - 999,999 ms
(*60,000 ms)
SDRTIM######
3-10
Aimer Delay 200 milliseconds
SCNDLY200
3-11
400 milliseconds
SCNDLY400
3-11
*Off (no delay)
SCNDLY0
3-11
User-Specified
Aimer Delay
Range 0 - 4,000 ms
SCNDLY####
3-11
Aimer Mode Off
SCNAIM0
3-12
Concurrent (4X00 default)
SCNAIM1
3-12
Interlaced (5X00 default)
SCNAIM2
3-12
Centering
Window
Centering On
DECWIN1
3-14
*Centering Off
DECWIN0
3-14
Left of Centering Window
(*40%)
DECLFT
3-14
Right of Centering Window
(*60%)
DECRGT
3-14
Top of Centering Window
(*40%)
DECTOP
3-14
Bottom of Centering Window
(*60%)
DECBOT
3-14
Decode Search
Mode
*Full Omnidirectional
DECMOD0
3-14
Quick Omnidirectional
DECMOD1
3-15
Advanced Linear Decoding
DECMOD2
3-15
Selection
Setting
* Indicates default
Serial
Command
# Indicates a
numeric entry