Loading...
3 - 16
Scan a barcode below to enable or disable Preferred Symbology.
High Priority Symbology
To specify the high priority symbology, scan the High Priority Symbology bar-
code below. On the Symbology Chart on page A-1, find the symbology you
want to set as high priority. Locate the Hex value for that symbology and scan
the 2 digit hex value from the Programming Chart (inside back cover). Scan
Save to save your selection.
Default = None
Low Priority Symbology
To specify the low priority symbology, scan the Low Priority Symbology barcode
below. On the Symbology Chart on page A-1, find the symbology you want to
set as low priority. Locate the Hex value for that symbology and scan the 2 digit
hex value from the Programming Chart (inside back cover).
If you want to set additional low priority symbologies, scan FF, then scan the 2
digit hex value from the Programming Chart for the next symbology. You can
program up to 5 low priority symbologies. Scan Save to save your selection.
Default = None
Preferred Symbology Time-out
Once you have enabled Preferred Symbology and entered the high and low pri-
ority symbologies, you must set the time-out period. This is the period of time
the imager will search for a high priority barcode after a low priority barcode has
been encountered. Scan the barcode below, then set the delay (from 100-
3,000 milliseconds) by scanning digits from the inside back cover, then scan-
ning Save.
Default = 500 ms.
* Preferred Symbology Off
Preferred Symbology On
High Priority Symbology
Low Priority Symbology
Preferred Symbology Time-out