7847i-E Installation and Setup Guide
3-4
PROMPTS ENTRY OPTIONS DESCRIPTION
16
Installation Key:
**********_
[0-9] Enter the 10-digit Installation Key necessary for
communication with receiver. If the key entry is invalid,
the prompt is repeated. See the Installation Key
paragraph in Section 1 for more information.
17
Verify Inst. Key:
**********_
Re-enter the 10-digit Installation Key to verify key.
If verification fails, “Verify NOT OK” will be displayed for
one second and the display will return to the entry of the
18
Primary City ID
(??)_
[01-99]
Enter the 2-digit primary city ID, 01-99 (decimal).
19
Primary CS ID
(??)
[01-FE]
Enter the 2-digit primary central station ID number, 01-FE
(HEX).
20
Primary Sub ID
(????)
[0001-9999]
Enter the 4-digit subscriber account number for the
primary central station, 0001-9999 (decimal).
21
Device Address
(03)_
[01-30]
In ECP mode, the 7847i-E communicates with the panel
as a communication (LRR) device. Enter the appropriate
ECP device address. For VISTA-10 and VISTA-20 series
control panels, use address 03. For other controls, see
the control panel’s Installation and Setup Guide.
NOTES:
1. When programming the control, enable the LRR output.
2. The device address must be unique from the "Keypad
Address" entered in Prompt 23.
22
Direct Wire Y/N
(N)_
[Y], [N]
Applies only to VISTA-128BP/250BP and FBP series
controls, and FA1600C and FA1700C series controls.
Enables Direct Wire Downloading over IP.
If [N], skip to Prompt 24: "Supervision."
23
Keypad Address
(28)_
[01-30]
Must be programmed if using Direct Wire downloading.
Enter the appropriate device address.
NOTES:
1. This address must also be programmed as an alpha
keypad in the control panel or an AUI (Advanced User
Interface) type device, if a full enhanced graphic
interface to the system is desired and the control panel
supports it. DO NOT connect an actual keypad (or any
other device) assigned to this address.
2. This address must be unique from the "Device Address"
24
Supervision
(24 Hours)_
• 24 Hours
• 1 Hour
• 6 Min
• 3 Min
• 90 Sec
• CN 90 Sec
• 75 Sec
• None
• 30 Day
The receiver must hear at least one supervisory message
from the module during this supervision period; otherwise,
the receiver notifies the central station that a
communication failure has occurred. (If the supervision
period is changed after registration, you must re-register
the module.)
Press the [space] key to scroll through choices.
Must be set to:
• 3 minutes for UL Comm Fire/Burg or ULC Active
Channel Security.
• 24hrs for ULC Passive channel security