Section 3: Programming the 7847i-E
3-7
ECP Status Codes
When the 7847i-E is configured for ECP mode, it sends status messages to the control panels
(e.g., VISTA-10P, VISTA-15P and VISTA-20P series), for tamper, and network connectivity
failures. Some of the control panels display these on the keypad as "LngRng Radio" followed
by a 4-digit code (listed in table 4). In addition, the Contact ID codes (listed in Appendix B)
for these conditions are sent to the central station by the module.
Table 4. Common ECP Keypad Displays Status Codes
STATUS CODE
DESCRIPTION
0000
Control panel lost communication with 7847i-E.
0880
Tamper detected (cover removed).
0005
Lost Ethernet connectivity.
000F
Not registered; account not activated.
0400
Power on reset AND the control panel lost communications with 7847i-E.
0C80
Power on reset AND tamper detected.
0C8F
Power on reset AND tamper detected AND not registered.
Alternative Zone Trigger Mode
Zone Trigger Mode
There are six input zones available on the 7847i-E. Zones 1 and 2 are located on TB1 pin 5
and are selectable for +V, V, or EOLR modes, which can detect both pulsed and steady
signals. The pulsed signal is reported as an alarm on zone 1 (Fire); the steady signal is
reported as an alarm on zone 2 (Burg). The implied pulse count for zone 1 is fixed to 3
pulses. No restores are reported for this zone.
Zones 3, 4, 5, 6 and 7 are voltage trigger inputs located on TB1 pins 6-10.
Alternative Mode Programming
Press the [ENTER] key to begin programming and follow the prompts for the mode of
operation being programmed.
NOTE:
The central station can remotely block access to
local device programming. If this has been done,
the following prompt appears:
Access to Prog
Mode Denied
Table 5: Programming a 7847i-E for Zone Trigger mode.
PROMPTS
ZONE
TRIG.
ENTRY OPTIONS DESCRIPTION
1
Strt Prog Mode?
Y/N_
[Y], [N]
Enters programming mode.
2
Enter Password
[0-9, A-F, N,
S, T, X, Y]
If a password has been previously assigned, this
prompt appears.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
The next prompt appears.
3
Program Device?
Y/N_
[Y], [N]
To begin programming the module, press [Y] and go to
Prompt 9: "Device Mode."
To create a password if none has been assigned,
press [N] and go to Prompt 4: Create Password.
To change an existing password, press [N] and go to
Prompt 5: "Change Password."
4
Create Password?
Y/N_
[Y], [N]
Passwords can be used to protect account and
programming information. If no password has been
assigned, this prompt appears after pressing [N] at the
"Program Device?" prompt.
If a password is desired, press [Y] and go to Prompt 6:
"Enter Password."
5
Change Password?
[Y], [N]
If a password has already been assigned, this prompt
appears after pressing [N] at the "Program Device?"