Section 3: Programming the 7847i-E
3-13
PROMPTS
ZONE
TRIG.
4204/
2-4204
ENTRY
OPTIONS
DESCRIPTION
30
Trip Inputs 1or2
w/Bell Out (N)_
[Y], [N]
Use if the zone 1 and 2 connection to the control's
bell output causes a bell fault on the control panel.
NOTES:
1. If used, EOLR trigger type is not available for
zones 1, 2 and 3.
2. Do not use with Lynx controls.
31
Telco Zone
(0)_
Zone Trig:
[3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
See Important Information Regarding Zone Input
Options on previous page.
Enter the zone number to be used for Telco line
fault reports. This zone assignment must be unique
from the Open/Close Zone selected in Prompt 35.
Zone Trigger Mode: If any zone is programmed for
"report only if armed," zone 7 cannot be used. If
Lynx Panic is enabled, zone 3 cannot be used.
4204 Mode: If any zone is programmed for "report
only if armed," zone 4 cannot be used.
2-4204 Mode: If any zone is programmed for "report
only if armed," or if tamper is enabled, zone 8
cannot be used.
NOTE: Connect the Telco line fault output (or relay
output programmed for "Telco line fault") to the
Telco zone.
32
Open/Close Zone
(0)_
Zone Trig:
[3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
Enter the zone number to be used for open/close
(arm/disarm) reports.
This zone assignment must be unique from the
Telco Zone selected in Prompt 34.
Zone Trigger Mode: If any zone is programmed for
"report only if armed," zone 7 cannot be used as an
open/close zone. If Lynx Panic is enabled, zone 3
cannot be used.
4204 Mode: If any zone is programmed for "report
only if armed," zone 4 cannot be used as an
open/close zone.
2-4204 Mode: If any zone is programmed for "report
only if armed," or if tamper is enabled, zone 8
cannot be used as an open/close zone.
NOTE: Connect an open/close (arm/disarm) trigger
(or relay output) from the control panel to the
open/close zone.
33
Zn1 Trigger Type
(V+)_
(EOLR)
(V+)
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
UL: V+ must be set as inverted and V- as non-
inverted
34
Invert Zn1 Y/N
(N)_
[Y], [N]
Inverts the alarm and normal states of the zone 1
trigger; otherwise uses normal input signal.
35
Restore Zn1 Y/N
(Y)_
[Y], [N]
Enables restore reporting for zone 1.
36
Delay Zn1 (secs)
(00)_
[01-15]
[00]=no delay
Defines the reporting delay in seconds for zone 1.
UL: Must be 00
37
Rpt Zn1 ONLY if
Armed (N)_
[Y], [N]
Report alarms on zone 1 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
38
Invert Zn2 Y/N
(N)_
[Y], [N]
Inverts the alarm and normal states of the zone 2
trigger; otherwise uses normal input signal.