Accenta/Optima Engineer’s Manual
25
6 = Zone Names
This option allows each of the eight zones to be given a name from the library (Appendix 2).
LCD Keypad:
• Press or to go to menu 6>Zone Names.
• Press [6] or to go to zone 1 descriptor.
• Press to scroll through the library to the desired
descriptor.
• Press the to go to the next zone.
• To assign additional zone descriptors repeat the above procedure.
• Press to save programming and leave the function.
LED Keypad:
The LED keypad cannot program zone names.
NOTE: The is not available on the LED keypad.
Timers
LCD keypad:
To change the Bell Time from 15 to 20 minutes:
• Press for menu 7>Timers.
• Press [7] or for option 71 Bell Time.
• Press [1] or . The Bell Time in minutes is displayed.
• The cursor is under the first digit. Select [2].
• The cursor moves to the second digit. Select [0].
• To accept the change press then
OR to cancel the change press the key twice.
7 = Timers
This option allows the Bell Time, Bell Delay and Rearm Count to be changed.
NOTE: The key takes you back to the first digit.
71 = Bell Time
This is the duration for which the external bell output is active.
The range is 01-99 minutes. The default is 15 minutes.
7>Timers
Bell Time
Minutes? 15
71>Bell Time
[7] or
7>Timers
then or
Bell Time
Minutes? 20
[2] and [0]
1: New Descriptor
1: Descriptor
[6] or
6>Zone Names
6>Zone Names
[1] or