Accenta/Optima Engineer’s Manual
43
LCD Keypad:
• Enter the premises by the agreed entry route. Thesystem
produces an entry tone. The LED is ON and the
LED is OFF indicating that the system is set.
• Enter your 4-digit code (0123 default).
• The system unsets with a double beep. The LED
comes ON indicating that the system is unset.
• After 30 seconds the date and time are displayed.
Resetting After an Alarm, Tamper or PA
The system may be programmed to be reset by the user or the installer. This is dependent on System flags set
up. See Menu 3, System Flags.
The duration of the audible alarm is subject to the Bell Time (menu 7.1=Timers.Bell Time)
NOTE: The user can reset a or Fire alarm only if the function is enabled in System Flags menu 3.1.4
and 3.1.5. respectively.
LED Keypad:
• Enter the premises by the agreed entry route. Thesystem
produces an entry tone. The LED is ON and the
LED is OFF indicating that the system is set.
• Enter your 4-digit code (0123 default).
• The system unsets with a double beep. The LED
comes ON indicating that the system is unset.
User Reset - LCD Keypad:
When system is in alarm or tamper:
• Enter a valid user code.
• Press . The LED goes OFF.
• The system unsets.
• After 30 seconds the system displays the date and time.
User Reset - LED Keypad:
• When system is in alarm or tamper:
• Enter a valid user code. The appropriate LED will flash.
• Press the key. The LED goes OFF.
• The system unsets. The LED is on.
Operating System (contd)
Unsetting the System
[4-digit code]
User Restore
Press Reset
Sunday 01-Jan
10:30
** SYSTEM UNSET **
[User Code]
Sunday 01-Jan
10:30
[4-digit code]
Sunday 01-Jan
10:30
** SYSTEM UNSET **