Accenta/Optima Engineer’s Manual
27
Timers (contd)
LED keypad:
To change the Bell Delay time from 00 to 12 minutes:
• Press [7] to enter Timers.LED’s 1, 2 and 3 are on.
• Press [2] for Bell Delay time in minutes. LED’s 1and 2
are on.
• Select [1] then [2]. LED’s 1 and 2 are on.
• To accept the change press . LED’s 1, 2 and 3
are on. Press .
OR to cancel the change press twice.
[7]
then
[2]
12
3
4
5
6
7
8
12
3
4
5
6
7
8
or
12
3
4
5
6
7
8
73 = Rearm Count
After an alarm the panel will automatically rearm itself when the external siren (Bell) timer has expired. Any
zones which still remain open at that time will be automatically omitted . The default is 3 rearms.
0 = no rearms
1-8 = number of rearms
9 = always rearm
LCD keypad:
To change the Rearm Count:
• Press for menu Timers.
• Press [7]or . Option 1 Bell Time appears.
• Press [3]. The Rearm Count is displayed (default 3).
• Select a number [0 - 9] to change the rearm count.
• To accept the change press then
OR to cancel the change press the key twice.
7>Timers
Rearm Count
3
[3]
71>Bell Time
[7] or
7>Timers
or
73>Rearm Count
then