ⅡC/ⅡB T4 Gb
North American: cETLus
Class I, Division 1, Groups A, B, C, & D, T4; Class I, Division 1, Groups
C, & D, T4
Performance Tests
Performance Requirements of Detectors for Flammable Gases
UL 60079-29-1:2019 Ed.2
CAN/CSA C22.2 NO. 60079-29-1:17 Ed.2
Wireless Approvals
FCC Part15; IC; RE-D (2014/53/EU)
(Contact us for wireless approval availability, country-specific)
RoHS RoHS Directive (EU) 2015/863
Noise Sensor
60 to 125dBA range (Response: 100Hz to 8kHz), 1dB resolution
A-weighted 15 second equivalent level. Updated every 5 seconds
External Ports Serial communication, switching, and 4-20mA Input
Safe Area Charge Port (AC CHG
SAFE AREA)
Battery charger input, DC5.7V 3A typical; Connect to AC/DC
adapter.
Field charge from IS
Barrier/Solar Panel (IS CHG
HAZARDOUS)
Line Power Supply input to extend Instrument Runtime. For Low
Power version only.
RAEMet Port (Serial) Optional; Port to RAEMet wind sensor.
Analog/Switch Input Port (4-
20MA IN)
Optional; 4-20mA signal input, X1 channel /Switch on/off signal
input, X1 channel
Relays Driver Output (SWITCH) Optional; Optocoupler, SPDT Normal Open, X3 channels
Languages
English, German, Spanish, Portuguese, Russian, Chinese, French,
Arabic
Warranty
• Two years on LEL, CO, H2S, and O2 sensors
• One year on other sensors
Specifications are subject to change.
BW RigRat 100 User Manual