EasyManua.ls Logo

Honeywell Dolphin CT60 - N6600 Slim Imager Engine Reading Distances

Honeywell Dolphin CT60
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Dolphin CT60 Mobile Computer 83
Note: To learn about changing the symbology settings, see
Change the Scanner Settings on
page 32.
N6600 Slim Imager Engine Reading Distances
The guaranteed depth of field measurements were taken using these parameters:
Distances are measured from the front of the engine.
+23 °C (+73 °F), 0 lux
Photographic quality codes
Note: Time to Read and Depth of Field are impacted if the bar code symbol is at the edge of
the image.
White Illumination Monochrome Sensor Only - Guaranteed Specs
White Illumination Monochrome Sensor Only - Typical Specs
UPC-A Enabled
UPC-E Enabled
UPC-E1 Enabled
1D Symbologies 2D Symbologies Postal Codes
Default Default Default
Focus Standard Range (SR)
Symbology Near Distance
(in/cm)
Far Distance
(in/cm)
Delta
(in/cm)
5 mil Code 39/128 3.6 (9.1) 5.6 (14.2) 2.0 (5.1)
10 mil Code 39/128 1.9 (4.8) 12.0 (30.5) 10.1 (25.6)
100% UPC 2.1 (5.3) 15.1 (38.1) 12.9 (32.7)
6.7 mil PDF 417 2.5 (6.4) 6.6 (16.7) 4.1 (10.4)
10 mil DataMatrix/Aztec 2.9 (7.4) 7.3 (18.5) 4.4 (11.1)
Focus Standard Range (SR)
Symbology Near Distance
(in/cm)
Far Distance
(in/cm)
Delta
(in/cm)
5 mil Code 39/128 2.5 (6.4) 6.4 (16.3) 3.9 (9.9)
10 mil Code 39/128 1.1 (2.8) 13.0 (33.0) 11.9 (30.2)
100% UPC 1.8 (4.6) 16.5 (41.9) 14.7 (37.3)
6.7 mil PDF 417 1.8 (4.6) 7.3 (18.5) 5.5 (14.0)
10 mil DataMatrix/Aztec 2.1 (5.3) 8.0 (20.3) 5.9 (15.0)