SPECIFICATIONS
Range: 16 m x 22 m
Power: 9.0 - 15 VDC; 9 mA typical, 14 mA maximum, 12 VDC;
AC Ripple: 3 V peak-to-peak at nominal 12 VDC
Alarm Relay: Energized Form A; 30 mA, 25 VDC, 22 Ohms
resistance maximum. Alarm Relay Duration: 3 seconds
Trouble Relay: Energized Form B; (NC) 30 mA, 25 VDC; 22 Ohms
resistance maximum
Tampers: Cover; (NC with cover installed) Form A;
30 mA, 25 VDC; Magnetic Field
Microwave Frequencies: DT8016MF4 - 10.525 GHz
DT8016MF5 - 10.587 GHz
RFI Immunity: 15 V/m, 80 MHz 2.7 GHz
PIR White Light Immunity: 10,000 Lux typical
Fluorescent light filter: 50 Hz / 60 Hz.
Operating Temperature: -10° to 55° C
Relative Humidity: 5 to 95%; non-condensing
Temperature Compensation: Advanced Dual Slope
Dimensions: 11.6 cm H x 7.0 cm W x 4.3 cm D
Weight: 135 g / 5 oz (net weight)
ACCESSORIES
SMB-10
(P/N 0-000-110-01)
Swivel Mount Bracket
SMB-10C
(P/N 0-000-111-01)
Swivel Mount Ceiling Bracket
SMB-10T
(P/N 0-000-155-01)
Swivel Mount Bracket w/Tamper
Note : The accessories are not covered by certifications.
APPROVAL LISTINGS
EN50131-2-4:2008, Security Grade 2,
Environmental Class II.
Suitable for connection to an EN 60950 Class
II Limited Power Source.
Note: In EN 50131-2-4 compliant installations, mount the sensor at 2.3m,
enable look down, set the microwave sensitivity to maximum and lock
the sensor housing with the cover lock (see “[EN]” where noted in
Steps 1-4).
IMPORTANT: The sensor should be tested at least once each year.
NF&A2P 2 boucliers (référentiel NF324-H58) et
conforme aux normes EN50131-2-4 et
RTC50131-2-4; IP30 IK04
DT8016MF4 N° de certificat: 2821420017
DT8016MF5 N° de certificat: 2821420018
Organisme de certification:
CNPP Cert. : www.cnpp.com et
AFNOR Cert.: www.marque-nf.com
Honeywell Security Group - BP1219
1198 avenue du docteur Maurice Donat
Sophia Antipolis
06254 Mougins Cedex.
TEL: +33.4.92.94.29.50
FAX: +33.4.92.94.29.60
DT8016MF4
INCERT B-893-0014
DT8016MF5
PD6662:2010
LARMKLASS 2
Corrente norminale: 12 =
Corrente massima
assorbita: 14 mA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell DT8016MF4 DUAL TEC and is the answer not in the manual?

Honeywell DT8016MF4 DUAL TEC Specifications

General IconGeneral
BrandHoneywell
ModelDT8016MF4 DUAL TEC
CategoryAccessories
LanguageEnglish

Related product manuals